Stairs

Use this calculator

A stair flight rises vertically through risers and travels horizontally through treads. Comfortable, code-compliant stair geometry depends on the number of risers, actual step dimensions, available run and applicable building rules.

Resolve whole risers from total rise

\mathrm{total\ rise}=N\times\mathrm{riser\ height}
N = whole riser count (minimum two); H = Total rise; rd = Desired riser height; ra = actual riser height. The active engine sets treads to N−1. If Available run is entered, actual tread depth is Available run/(N−1). All lengths are in consistent metric units.

Resolve whole risers from total rise

N = whole riser count (minimum two); H = Total rise; rd = Desired riser height; ra = actual riser height. The active engine sets treads to N−1. If Available run is entered, actual tread depth is Available run/(N−1). All lengths are in consistent metric units.

Resolve whole risers from total rise

Actual stair geometry follows a whole number of risers and treads.

N = whole riser count (minimum two); H = Total rise; rd = Desired riser height; ra = actual riser height. The active engine sets treads to N−1. If Available run is entered, actual tread depth is Available run/(N−1). All lengths are in consistent metric units.

Enter the stair-flight geometry

ModeExact visible fields (unit; defaults where supplied)
Stair designTotal rise (mm); Desired riser (mm); Desired tread (mm); Advanced: Available run (mm); Stair width (mm) [default 1000]

Calculate a coherent stair flight

Select Stair design. Enter Total rise, Desired riser and Desired tread in millimeters. In advanced fields, Available run and Stair width can be entered when those dimensions are known. Calculate to see the rounded riser count and actual dimensions rather than assuming desired rise divides total rise exactly.

Whole risers and actual step sizes

The primary result is Number of risers. Details show actual riser, Number of treads, actual tread, Total run, Stringer length and a “2R + T” reference measure. The latter is a geometric comfort reference, not a building-code approval or structural check.

Count vertical transitions explicitly

For a total rise of 2800 mm and desired riser 175 mm, the count is 16 and the actual riser remains 175 mm. A normal straight flight then has 15 treads when the top landing is counted separately.

Riser count rounding changes the actual rise dimension.

For a total rise of 2800 mm and desired riser 175 mm, the count is 16 and the actual riser remains 175 mm. A normal straight flight then has 15 treads when the top landing is counted separately.

Test space along the floor

With 15 treads of 280 mm, total run is 4200 mm. If the measured Available run is 3900 mm, actual tread becomes 260 mm while the riser count stays 16.

Available horizontal run redistributes tread depth while riser count stays fixed.

With 15 treads of 280 mm, total run is 4200 mm. If the measured Available run is 3900 mm, actual tread becomes 260 mm while the riser count stays 16.

Translate geometry into construction checks

Confirm headroom, landing size, nosing, handrails and permissible riser/tread dimensions against the local adopted code and stair use category before constructing.

Quick answers

Why can actual riser differ from Desired riser?

The calculator rounds the number of whole risers, then divides Total rise equally.

What does Available run change?

It changes calculated actual tread depth when entered.

Does the calculator certify a stair design?

It reports geometric values and a 2R + T reference; site-specific code and structural checks are separate.