Dew Point
Dew point is the temperature to which an air sample must cool, at approximately constant pressure and water-vapour content, to become saturated. A dew point closer to the current air temperature indicates less cooling is needed before condensation begins.
The governing equation
\gamma=\ln\!\left(\frac{RH}{100}\right)+\frac{17.625T}{243.04+T},\quad T_d=\frac{243.04\gamma}{17.625-\gamma}The governing equation
The governing equation
Two measurements for moisture estimation
Air temperature [°C] Signed temperature; negative temperatures are accepted.
Relative humidity [%] Strictly greater than 0 and at most 100.
Enter temperature and RH
Enter Air temperature and Relative humidity in Calculate. Example: 25 °C and 60% RH yield dew point about 16.7 °C. The calculator uses the two-step Magnus approximation and returns one temperature.
Dew point and its meaning
The primary answer is Dew point (°C). Input RH = 0 is rejected because ln(RH/100) is undefined; RH = 100% makes the dew-point calculation approximately equal to air temperature.
Temperature–dew-point spread
The difference T − T_d indicates how much cooling is needed for saturation under the simplified assumptions. A small spread is common in humid conditions; this spread is an explanatory calculation, not an app output.
The difference T − T_d indicates how much cooling is needed for saturation under the simplified assumptions. A small spread is common in humid conditions; this spread is an explanatory calculation, not an app output.
Condensation on cold surfaces
If air near a surface cools to its dew point, water vapour may condense on that surface. The diagram shows cooling toward saturation rather than treating relative humidity as a volume of liquid water.
If air near a surface cools to its dew point, water vapour may condense on that surface. The diagram shows cooling toward saturation rather than treating relative humidity as a volume of liquid water.
Why humidity percentage depends on temperature
At identical atmospheric water-vapour content, warmer air can have lower RH. Dew point often gives a more stable way to express moisture than RH alone when comparing differently heated air.
At identical atmospheric water-vapour content, warmer air can have lower RH. Dew point often gives a more stable way to express moisture than RH alone when comparing differently heated air.
Quick answers
What happens when RH is 100%?
The estimated dew point is approximately the current air temperature.
Why is 0% humidity rejected?
The Magnus calculation uses ln(RH/100), which has no finite value at zero.
What units does the result use?
Degrees Celsius (°C).